{"id":1373,"date":"2021-11-07T00:00:00","date_gmt":"2021-11-06T23:00:00","guid":{"rendered":"https:\/\/preprod.retinegallien.com\/publication\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\/"},"modified":"2021-11-07T00:00:00","modified_gmt":"2021-11-06T23:00:00","slug":"lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc","status":"publish","type":"publication","link":"https:\/\/www.retinegallien.com\/en\/publication\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\/","title":{"rendered":"Lux study: Contribution of a three-dimensional, high dynamic range, ultra-high-definition heads-up visualization system to a significant delivered light intensity decrease during different types of ocular surgeries"},"content":{"rendered":"<p>Journal Fran\u00e7ais d&#8217;Ophtalmologie October 2021Volume 44, Issue 8 Pages 1129-1141&nbsp;<br \/>\n<strong>L. V\u00e9lasque&nbsp;<\/strong><strong>,&nbsp;<\/strong>N. Arbousoff, F. Rigaudier, M. Dominguez, E. Fourmaux, L. Rosier, C. Seguy<br \/><\/br \/>Summary<br \/>\nObjective<\/p>\n<p>To explore the hypothesis that using a large, three-dimensional (3D), ultra-high-definition (4K), heads-up display (HUD) system in a real-life setting may be associated with a significant reduction in light intensity (LI) delivered during various types of eye surgery.<\/p>\n<p>\nMethods<\/p>\n<p>Single center, post-learning curve observational study of 142 independent consecutive cases: 73 cataracts and 69 vitrectomies (VR). For each group, the only variable setting was the LI. The LI delivered by each source was calibrated in lumens (lm).<\/p>\n<p>\nResults<\/p>\n<p>In the VR group, the delivered LI dramatically decreased from the 80% reference to 27.8%&nbsp;\u00b1&nbsp;13.2% (<em>P<\/em>&nbsp;&lt;&nbsp;0.0001) (4.3 to 1.5&nbsp;lm). Among these surgeries, 91.3% needed 40% or less LI (2.3&nbsp;lm). The corneal transparency and quality of pupil dilation showed some correlation with the results. In the cataract group, the difference was even more spectacular, from 80% to 15%&nbsp;\u00b1&nbsp;11.3% (<em>P<\/em>&nbsp;&lt;&nbsp;0.0001) (2.5 to 0.3&nbsp;lm). Among these surgeries, 80.8% required less than 20% LI (0.5&nbsp;lm). The surgical time, LI variations and type of cataract seemed to influence the results, down to 9.6%&nbsp;\u00b1&nbsp;5.4% (<em>P<\/em>&nbsp;&lt;&nbsp;0.0001) (0.22&nbsp;lm) for nuclear cataracts, which represented 63% of the cataract sample.<\/p>\n<p>\nConclusion<\/p>\n<p>The digital signal amplification with this HUD system allows comfortable posterior as well as anterior segment surgery despite the decrease in incident light, suggesting an unprecedented reduction in the risk of phototoxicity compared to conventional systems as well as a likely improvement in patient comfort.<\/p>\n","protected":false},"featured_media":1245,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false},"class_list":["post-1373","publication","type-publication","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Lux study: Contribution of a three-dimensional, high dynamic range, ultra-high-definition heads-up visualization system to a significant delivered light intensity decrease during different types of ocular surgeries - R\u00e9tine Gallien<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.retinegallien.com\/en\/publication\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Lux study: Contribution of a three-dimensional, high dynamic range, ultra-high-definition heads-up visualization system to a significant delivered light intensity decrease during different types of ocular surgeries - R\u00e9tine Gallien\" \/>\n<meta property=\"og:description\" content=\"Journal Fran\u00e7ais d&#8217;Ophtalmologie October 2021Volume 44, Issue 8 Pages 1129-1141&nbsp; L. V\u00e9lasque&nbsp;,&nbsp;N. Arbousoff, F. Rigaudier, M. Dominguez, E. Fourmaux, L. Rosier, C. SeguySummary Objective To explore the hypothesis that using a large, three-dimensional (3D), ultra-high-definition (4K), heads-up display (HUD) system in a real-life setting may be associated with a significant reduction in light intensity (LI) [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.retinegallien.com\/en\/publication\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\/\" \/>\n<meta property=\"og:site_name\" content=\"R\u00e9tine Gallien\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.retinegallien.com\/wp-content\/uploads\/2025\/03\/IMG-7954-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t<meta property=\"og:image:height\" content=\"225\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.retinegallien.com\\\/en\\\/publication\\\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\\\/\",\"url\":\"https:\\\/\\\/www.retinegallien.com\\\/en\\\/publication\\\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\\\/\",\"name\":\"Lux study: Contribution of a three-dimensional, high dynamic range, ultra-high-definition heads-up visualization system to a significant delivered light intensity decrease during different types of ocular surgeries - R\u00e9tine Gallien\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.retinegallien.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.retinegallien.com\\\/en\\\/publication\\\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.retinegallien.com\\\/en\\\/publication\\\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.retinegallien.com\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/IMG-7954-2.jpg\",\"datePublished\":\"2021-11-06T23:00:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.retinegallien.com\\\/en\\\/publication\\\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.retinegallien.com\\\/en\\\/publication\\\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.retinegallien.com\\\/en\\\/publication\\\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.retinegallien.com\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/IMG-7954-2.jpg\",\"contentUrl\":\"https:\\\/\\\/www.retinegallien.com\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/IMG-7954-2.jpg\",\"width\":300,\"height\":225},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.retinegallien.com\\\/en\\\/publication\\\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\",\"item\":\"https:\\\/\\\/www.retinegallien.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Lux study: Contribution of a three-dimensional, high dynamic range, ultra-high-definition heads-up visualization system to a significant delivered light intensity decrease during different types of ocular surgeries\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.retinegallien.com\\\/#website\",\"url\":\"https:\\\/\\\/www.retinegallien.com\\\/\",\"name\":\"R\u00e9tine Gallien\",\"description\":\"Cabinet Ophtalmologie \u00e0 Bordeaux\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.retinegallien.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.retinegallien.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.retinegallien.com\\\/#organization\",\"name\":\"R\u00e9tine Gallien\",\"url\":\"https:\\\/\\\/www.retinegallien.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.retinegallien.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.retinegallien.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/www.retinegallien.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/logo.png\",\"width\":322,\"height\":161,\"caption\":\"R\u00e9tine Gallien\"},\"image\":{\"@id\":\"https:\\\/\\\/www.retinegallien.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Lux study: Contribution of a three-dimensional, high dynamic range, ultra-high-definition heads-up visualization system to a significant delivered light intensity decrease during different types of ocular surgeries - R\u00e9tine Gallien","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.retinegallien.com\/en\/publication\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\/","og_locale":"en_US","og_type":"article","og_title":"Lux study: Contribution of a three-dimensional, high dynamic range, ultra-high-definition heads-up visualization system to a significant delivered light intensity decrease during different types of ocular surgeries - R\u00e9tine Gallien","og_description":"Journal Fran\u00e7ais d&#8217;Ophtalmologie October 2021Volume 44, Issue 8 Pages 1129-1141&nbsp; L. V\u00e9lasque&nbsp;,&nbsp;N. Arbousoff, F. Rigaudier, M. Dominguez, E. Fourmaux, L. Rosier, C. SeguySummary Objective To explore the hypothesis that using a large, three-dimensional (3D), ultra-high-definition (4K), heads-up display (HUD) system in a real-life setting may be associated with a significant reduction in light intensity (LI) [&hellip;]","og_url":"https:\/\/www.retinegallien.com\/en\/publication\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\/","og_site_name":"R\u00e9tine Gallien","og_image":[{"width":300,"height":225,"url":"https:\/\/www.retinegallien.com\/wp-content\/uploads\/2025\/03\/IMG-7954-2.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.retinegallien.com\/en\/publication\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\/","url":"https:\/\/www.retinegallien.com\/en\/publication\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\/","name":"Lux study: Contribution of a three-dimensional, high dynamic range, ultra-high-definition heads-up visualization system to a significant delivered light intensity decrease during different types of ocular surgeries - R\u00e9tine Gallien","isPartOf":{"@id":"https:\/\/www.retinegallien.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.retinegallien.com\/en\/publication\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\/#primaryimage"},"image":{"@id":"https:\/\/www.retinegallien.com\/en\/publication\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\/#primaryimage"},"thumbnailUrl":"https:\/\/www.retinegallien.com\/wp-content\/uploads\/2025\/03\/IMG-7954-2.jpg","datePublished":"2021-11-06T23:00:00+00:00","breadcrumb":{"@id":"https:\/\/www.retinegallien.com\/en\/publication\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.retinegallien.com\/en\/publication\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.retinegallien.com\/en\/publication\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\/#primaryimage","url":"https:\/\/www.retinegallien.com\/wp-content\/uploads\/2025\/03\/IMG-7954-2.jpg","contentUrl":"https:\/\/www.retinegallien.com\/wp-content\/uploads\/2025\/03\/IMG-7954-2.jpg","width":300,"height":225},{"@type":"BreadcrumbList","@id":"https:\/\/www.retinegallien.com\/en\/publication\/lux-study-contribution-of-a-three-dimensional-high-dynamic-range-ultra-high-definition-heads-up-visualization-system-to-a-significant-delivered-light-intensity-decrease-during-different-types-of-oc\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"","item":"https:\/\/www.retinegallien.com\/"},{"@type":"ListItem","position":2,"name":"Lux study: Contribution of a three-dimensional, high dynamic range, ultra-high-definition heads-up visualization system to a significant delivered light intensity decrease during different types of ocular surgeries"}]},{"@type":"WebSite","@id":"https:\/\/www.retinegallien.com\/#website","url":"https:\/\/www.retinegallien.com\/","name":"R\u00e9tine Gallien","description":"Cabinet Ophtalmologie \u00e0 Bordeaux","publisher":{"@id":"https:\/\/www.retinegallien.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.retinegallien.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.retinegallien.com\/#organization","name":"R\u00e9tine Gallien","url":"https:\/\/www.retinegallien.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.retinegallien.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.retinegallien.com\/wp-content\/uploads\/2024\/12\/logo.png","contentUrl":"https:\/\/www.retinegallien.com\/wp-content\/uploads\/2024\/12\/logo.png","width":322,"height":161,"caption":"R\u00e9tine Gallien"},"image":{"@id":"https:\/\/www.retinegallien.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.retinegallien.com\/en\/wp-json\/wp\/v2\/publication\/1373","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.retinegallien.com\/en\/wp-json\/wp\/v2\/publication"}],"about":[{"href":"https:\/\/www.retinegallien.com\/en\/wp-json\/wp\/v2\/types\/publication"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.retinegallien.com\/en\/wp-json\/wp\/v2\/media\/1245"}],"wp:attachment":[{"href":"https:\/\/www.retinegallien.com\/en\/wp-json\/wp\/v2\/media?parent=1373"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}